Model |
KL |
KG |
KH |
2.4 In Display Screen |
No |
Yes |
Yes |
Shunt Housing |
No |
No |
Yes |
Protection Sound Alarm |
No |
No |
Yes |
Temperature Display |
Celsius |
Celsius |
Fahrenheitor Celsius |
Display Time |
No |
No |
Local Time |
Bluetooth password |
No |
No |
Support Modification |
Voltage current curve |
Yes |
Yes |
Yes |
Data Record |
Yes |
Yes |
Yes |
Mobile APP |
Yes |
Yes |
Yes |
Data Cable Length |
No |
3 meters |
5 meters |
KG-F series User Manual: http://68.168.132.244/KG-F_EN_manual.pdf
Android phone App link: http://68.168.132.244/app/KG.apk
IOS mobile App link: Search Apple Store for "KG Series"
KG-F series firmware upgrade log: http://68.168.132.244/KG/KG-F_DFU_log_20220410_EN.pdf
Quick Installation Video: https://www.youtube.com/watch?v=C5G0iR-kUr8
Wiring video :https://www.youtube.com/watch?v=GMs71vDMPnM
Operation video: https://www.youtube.com/watch?v=rO4zFgKY_NA&t
Mobile APP control video: https://www.youtube.com/watch?v=1ixb0Ddaf4g&t
KG-F series color screen wireless bluetooth battery coulomb meter is a professional instrument for monitoring battery power, and it can also monitor the voltage, current, power, ambient temperature, and energy of the battery during charging and discharging.Real-time display of how long the battery can be fully charged and How long can the battery be discharged, lead-acid batteries, lithium batteries, iron-lithium batteries and all other batteries can be used. |
?Automatically identify the current in both charging and discharging directions;
?Using current*working time to calculate the capacity of charging and discharging is more accurate than calculating the remaining capacity by voltage;
?The mobile APP can connect to the meter through wireless Bluetooth to view data and set parameters;
?The mobile phone APP can upgrade the firmware of the measurement module;
?The mobile APP can view the real-time curve and historical curve of voltage and current, and support historical data export;
?The shunt and the screws are made of pure copper material, and the power consumption in standby mode is very low;
?After configuring the relay, it can realize over-voltage protection, under-voltage protection, over-current protection, over-temperature protection, Low temperature protection and over-power protection (the delivery list does not include relays)
?The parameters of voltage, current and temperature can be calibrated by themselves;
?The display and measurement module are connected through a 3 meter telephone line, and the maximum length can be extended to 30 meters, which is more convenient for installation;
?The color of the casing may have varying degrees of color difference due to the influence of shooting light and display color, and color difference issues cannot be used as a reason for disputes!
Model |
KG110F |
KG140F |
KG160F |
Sampling method |
Shunt |
Shunt |
Shunt |
Voltage measurement range(External power supply) |
0-120V |
0-120V |
0-120V |
Voltage measurement range(Self-powered) |
10-80V |
10-80V |
10-80V |
Voltage resolution |
0.01V |
0.01V |
0.01V |
Current measurement range |
0~100A |
0~400A |
0~600A |
Current resolution |
0.01A |
0.1A |
0.1A |
Relay |
optional |
||
Temperature measurement range |
-20-120℃ |
||
Capacity display range |
0%~100% |
||
Power measurement range |
0~72KW |
||
Power resolution |
0.01W |
||
AH measurement range |
0~9999.99AH |
||
Capacity resolution |
0.001AH |
||
Watt-hour measurement range |
0~9999.99kWH |
||
Watt-hour accuracy |
0.001WH |
||
Time measurement range |
0~999:59:59S |
||
Time resolution |
1second |
||
Bluetooth communication distance |
10m |
||
Voltage accuracy |
±1%+2 characters |
||
Current accuracy |
±1%+5 characters |
||
Sampling rate |
1time /second |
||
Measuring module power consumption |
About 0.4W |
||
Display module power consumption |
About 0.5W |
||
Over power protection |
0-99999.99W |
||
Negative overcurrent protection |
0~50A/100A/400A/600A |
||
Forward overcurrent protection |
0~50A/100A/400A/600A |
||
Overvoltage protection |
0~120V/600V |
||
Undervoltage protection |
0~120V/600V |
||
External over temperature protection |
0-120℃ |
||
Protection recovery time |
0-99s |
||
Enter standby time |
0-60s |
||
Delay time setting |
0-99S |
||
Mailing address |
There are 99 P01-P99, P00 is the broadcast address |
The interface cool function is powerful to use mobile app, can operate remotely, support data recording and export, convenient and quick. |
Mobile app supports curve display, real-time curve and history curve of voltage and current, and historical data export. |
?Over voltage, under voltage, over current, over power and external
over temperature protection can be set,When the value is not in the
range of protection value,the output state of the meter is turned off
(cooperation is required) The relay is used to prevent the electrical
equipment from being damaged.
?The protection recovery time and delay time can be set, which is
suitable for various occasions.
OVP |
Over Voltage Protection |
LTP |
Low temperature protection |
OTP |
Over Temperature Protection |
LVP |
Low Voltage Protection |
OPP |
Over Power Protection |
OCP |
Over Current Protection |
NCP |
Negative Over Current Protection |
Suitable for all batteries within the voltage measurement rangeand the actual capacity value of the battery can be set.
1> Display Module*1 |
5> 3P Terminal*1 |
2> Measuring Module* |
6> 3m Communication Cable* 1 |
3> Sampler*1 |
7> 3P Connection Cable*1 |
4> Temperature Sensor*1 |
8> 4P Connection Cable*1 |